Laerdal Capable Nursing Anne
The Laerdal Capable Nursing Anne is a highly effective manikin meant for realistic simulation of various clinical skills to treat in-hospital patients. The training includes teaching students different methods and techniques in care and management of a patient. Anne is particularly for women patient simulation and has a flexible design that is perfect to teach obstetrics, wound assessment and care, post-partum and general assessment and care.
This is an economical and educationally efficient skills and scenario-based trainer. Students can practice medication dose calculations and administration through intramuscular injections at the deltoid, gluteal, ventrogluteal, and thigh sites. Moreover, multiple accessory modules can be added to the manikin for use in multiple clinical settings. Its durable and rugged design is made to withstand years of use.
Features:
- NG tube insertion care, medication administration and removal; gastric lavage and gavage.
- Tracheostomy care and tracheal suctioning.
- Articulating IV training arm allows peripheral intravenous therapy with IV bolus or push injection. Venipuncture possible in the antecubital fossa or dorsum of hand.
- Optional mastectomy Module can be used to practice postsurgical mastectomy care procedures.
- Interchangeable genitalia with connectors & urinary and colon reservoirs facilitate urologic care procedures and gastrointestinal procedures.
- Wound Care and Assessment Set can be added to the Nursing Anne manikin simulator for realism in wound assessment and patient care scenarios.
Patient Care:
- Head with anatomical landmarks, trachea, and esophagus, along with simulated lungs and stomach, allow the practice of many procedures
- Irrigation of the eye and ear (simulated)
- Application/instillation of medications in the eye, ear and nose including nasal packing
- Mouth and denture care procedures
- Insertion and suctioning of oropharyngeal and nasopharyngeal airways
- Insertion, securing, and care of endotracheal tubes
- Tracheostomy care and tracheal suctioning
- Various oxygen delivery procedures
- NG tube insertion, care, medication administration, and removal
- Gastric lavage and gavage
- Subclavian, jejunostomy and Hickman catheter openings (placement only)
- Manually generated carotid pulse
- Deltoid, dorsogluteal, and vastus lateralis IM injections possible
- Full range of motion for realistic patient handling
- Interchangeable stomas depict colostomy, ileostomy and suprapubic cystotomy
- Colostomy may be irrigated and will retain an indwelling catheter
- Fingers and toes are spread to allow bandaging
Interchangeable Male and Female Genitalia:
- Complete urinary catheterization
- Can be attached to urinary and colon reservoirs via connector valves
- Female genitalia capable of vaginal douching
- Will retain indwelling or straight catheter
- Enema procedures may be performed using fluid for realistic return
- When used with manikin, fluid may be used for realistic return
- Urinary valves give the natural resistance felt when catheterizing
- Anal valves simulate the internal anal sphincter
Circulatory Skills and IV Drug Administration:
- Articulating IV training arm with replaceable skin and infusible vein system allows peripheral intravenous therapy and site care
- Venipuncture possible in the antecubital fossa and dorsum of the hand
- Accessible veins include median, basilic and cephalic
|
Sounds:
- Heart sounds synchronized with programmable ECG
- Auscultated lung sounds synchronized with breathing rate, 0 - 60 BPM
- Individual lung or bilateral sound selection
- Normal or abnormal bowel sounds
- Vocal sounds – computer-generated sounds, mixed with voice input (via microphone sold separately)
Heart Sounds:
- Aortic Stenosis
- Friction Rub
- Austin Flint Murmur
- Diastolic Murmur Mi Stenosis
- Systolic Murmur
- Mitral Valve Prolapse
- Normal Heart Sounds – Apex
- Opening Snap Msec
- Ventricular Septal Defect
- Atrial Septal Defect
- Pulmonary Stenosis
- Stills Murmur
- Normal Heart Sounds
Lung Sounds:
- Coarse Crackles
- Fine Crackles
- Normal Breath Sounds
- Pneumonia
- Stridor
- Wheeze
- Pleural Rub
- Rhonchi
|
Blood Pressure / Pulses:
- Articulating blood pressure arm for auscultated and palpated blood pressure simulation
- Korotkoff sounds synchronized with ECG
- Korotkoff sounds volume control in 10 steps, 0-9
- Systolic and diastolic pressure may be set individually in steps of 2mmHG
- Systolic 0-300mmHG, Diastolic 0-300 mmHG
- Auscultative Gap, with on/off feature
- Pressure accuracy +/- 4mmHG
- Calibrate function to adjust pressure sensor and cuff gauge
- Palpated pulse simulator controls brachial and radial pulses
- Pulses only active when palpated
- Pulses synchronized with programmable ECG
- Pulse strengths dependent on Blood Pressure
SimPad PLUS System Features:
- Handheld, intuitive touchscreen remote for easy 'pick up and play' experience
- Operate on-the-fly or utilize Scenarios and Themes for consistent simulation training
- Optimal data capture for quality debriefing
- Mobile - teach anywhere
- Optional patient monitor provides clinical realism
|
Bowel Sounds:
- Borborygmus
- Fetal Tones
- Hyperactive Bowel
- Hypoactive Bowel
- Normal Bowel
Vocal Sounds:
- Cough
- Vomit
- Moan
- Scream
- SOB Breathing
- Yes
- No
- Hiccup (infant)
- Cry (infant)
| |
NAS-LG02165, NAS LG02165, LG02165, NASLG02165, 325-20050, 325-05050, 325 20050, 325 05050, 32520050, 32505050, NAS-LG02165U, NAS LG02165U, LG02165U, NASLG02165U, 325-20050, 325-05050, 325 20050, 325 05050, 32520050, 32505050