NOTICE of RESTRICTIONS on MMC Kits:
Please note that we restrict these Test Kits from sale to the public and
Ship Directly to Law Enforcement Related Agencies Only. If you are authorized by an agency for purchase of these items. Please acknowledge this restriction upon making your selection above. If we require additional information such as your credentials, we will contact you before filling your order. Thank you for your understanding and support.
MMC V&R Valium Rohypnol Drug Test Kit R
This test is used for the presumptive identification of Valium (Diazepam®) and Rohypnol Flunitrazepam®).
10 tests per pack
The MMC Narcotic Field Tests are based on a new technology with many advantages over the tests available in the market today.
Advantages:
- Very little liquid reagents
- One step tests (one ampoule only)
- Safe and easy to use
- Acid neutralizers are not required
- No environmental risks/concerns
- Results within seconds
- High reliability and consistency
- Accurate and sensitive
- Economic (low cost)
- Easy to test liquid narcotics and precursors
- No hazardous shipping concerns
- No concern of over or under loading the ampoule with suspected drugs
MMC V & R TEST
APPLICATION:
Used as a presumptive test to detect the presence of Valium and Rohypnol powder. The test has a SENSITIVITY; LDL (Lower Detection Level) of < 0,5 mg depending on the purity of the sample. The colour of the reagent will be light to dark brown rust Take an ampoule and note whether the crystals are still bright. . (Reagent = Rust – Brown) Compare the colour changes with the colour indicated on the ampoule (Each ampoule can be used only once)
How to use the test:
Remove the sealing cap and open the ampoules as follows: Take the lower part of the ampoule in the left hand, and take the top (upper part) between index finger and thumb and snap off at the fracture line by applying pressure to the side.
There are two ways to finish the test:
- Transfer a little of the sample under examination into the plastic cap and put this cap on top of the opened ampoule and turn the ampoule upside-down so the material will fall down .
- Keep the ampoule in the upright position so that the substance is deposit on
the bottom of the ampoule. And transfer the suspected material into the ampoule.
Allow the suspected material and the reagents/granulate to mix. This can be
achieved by tapping the ampoule with the finger or with a light shake or merge
with the round side of the spatula. In case of the presence of rohpynol and
valium powder the crystals /liquid will turn into light / dark lavender (within
seconds). In all cases the colour change is fully developed within 1-2 minutes.
A further elapse of time produces only a slight colour change depending of the
colour. The test should be evaluated after 1-2 minutes have elapsed.
NOTE: For both methods it is recommended that a clean spatula is used. A further elapse of time produces only a slight change, depending on the colour.
SPECIFICITY: The test is very specific for valium and rohpynol
STORAGE: How to store the ampoules:The ampoules should be protected from light and temperatures over 35 ºC.(F 95)
SAFETY: Keep the ampoules out of the reach of children. In case the crystals come in contact with the eyes, skin or clothes, the effected areas have to be rinsed with water.
DISPOSAL: After use the ampoules we recommend to dispose the test ampoules into the bottle bank . Or in accordance with the waste Disposal regulations current in the country use.
PACKING: 10 Test Ampoules - 10 Spatulas - 01 Instruction sheet
VR, MMCVR